BLCFQ - CPS 5000 SERIES COLOR #16515 GRAY 941 SP

  • MSDS: BLCFQ
  • Manufacturer: CORROSION PROTECTION SYSTEMS
  • Product Name: CPS 5000 SERIES COLOR #16515 GRAY 941 SP
  • National Stock Number: 8010-00N017262
Product Identification

Product ID:CPS 5000 SERIES COLOR #16515 GRAY 941 SP
MSDS Date:08/30/1989
FSC:8010
NIIN:00N017262
MSDS Number: BLCFQ

Responsible Party
CORROSION PROTECTION SYSTEMS
13214 SOUTH CHOCTAW DRIVE
BATON ROUGE, LA 70815
US

Emergency Phone: 504-272-5540

Info Phone: 504-272-5540

Cage: 8R664

Contractor
CORROSION PROTECTION SYSTEMS,INC
BATON ROUGE, LA 70815 US

Telephone: 504-272-5540

Cage: 8R664

Ingredients

VM & P NAPHTHA

CAS: 64742-89-8

OSHA PEL 300 PPM;400 PPM STEL

ACGIH TLV: 300 PPM;


USING A CUFFED ENDOTRACHEAL TUBE SHOULD BE

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: VAPORS MAY BE IRRITATING TO
NOSE, THROAT & RESPIRATORY TRACT. HIGH VAPOR CONCENTRATION MAY
CAUSE CNS DEPRESSION. SKIN: LIQUID IS SLIGHTLY IRRITATING TO THE
SKIN. PROLONGED OR REPEATED CONTACT C AN RESULT IN DEFATTING &
DRYING OF THE SKIN WHICH MAY RESULT IN SKIN IRRITATION &
DERMATITIS. INGEST:(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: INGESTION OF PRODUCT MAY RESULT IN
VOMITTING: ASPIRATION OF VOMITUS INTO THE LUNGS MUST BE AVOIDED AS
EVEN SMALL QUANTITIES MAY RESULT IN ASPIRATION PNEUMONITIS.
Medical Cond Aggravated by Exposure:PREEXISTING EYE, SKIN AND
RESPIRATORY DISORDERS MAY BE AGGREVATED BY EXPOSURE TO THIS
PRODUCT.

First Aid

First Aid:SKIN:REMOVE CONTAM CLTHG/SHOES. FLUSH SKIN W/H*2O. FOLLOW BY
WASHING W/SOAP & H*2O. IF IRRIT OCCURS, GET MED ATTN. DO NOT REUSE
CLTHG UNTIL CLEANED. INHAL:REMOVE TO FRESH AIR & PROVIDE O*2 IF
BRTHG IS DIFFICULT. GIVE ARTF RESP IF NOT BRTHG. GET MED ATTN.
INGEST: DO NOT INDUCE VOMIT. IF VOMIT OCCURS SPONTANEOUSLY, KEEP
HEAD BELOW HIPS TO PREVENT ASPIR OF LIQ INTO LUNGS. GET MED
ATTN.(SUPP DATA)

Fire Fighting

Flash Point Method:TCC
Flash Point:60.0F,15.6C
Lower Limits:1 %
Upper Limits:6 %
Extinguishing Media:DRY CHEMICAL, CO*2 AND FOAM.
Fire Fighting Procedures:A STRAIGHT STREAM OF WATER WILL SPREAD FIRE.
WEAR NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:A VAP ACCUM WILL FLASH &/OR EXPLO, IF
IGNIT. CNTNRS MAY BURST EXPO IF OVER HEATED IN FIRE. COOL W/H*2O
SPRAY OF FOG. EMPTY CNTNRS ALSO PRESENT FIRE &(SUPP DATA)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. PROVIDE
ADEQUATE VENTILATION. AVOID BREATHING VAPORS. SHUT OFF SOURCE OF
SPILL IF IT CAN BE DONE SAFELY. USE NON-SPARKING TOOLS. ABSORB ON
ABSORBANT MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN ORIGINAL TIGHTLY CLOSED
CONTAINER IN A COOL, DRY PLACE AWAY FROM ALL SOURCES OF IGNITION.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED AIR SUPPLIED OR SCBA IN
AREAS OF HIGH VAPOR CONCENTRATIONS.
Ventilation:LOCAL EXHAUST AS REQUIRED TO KEEP VAPOR CONCENTRATIONS
BELOW THE THRESHOLD LIMIT VALUE.
Protective Gloves:RECOMMENDED
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:AS REQUIRED TO AVOID WETTING CLOTHING AND
SKIN.
Work Hygienic Practices:AVOID CONTACT WHERE POSSIBLE.
Supplemental Safety and Health
EXPLO HAZ: EXPLO HAZ DUE TO RESIDUAL VAPS. FIRST AID PROC: NOTE TO MD:
IF MORE THAN 2.0 ML/KG HAS BEEN INGESTED & VOMITING HAS NOT
OCCURED, EMESIS SHOULD BE INDUCED W/SUPERVISION. KEEP VICTIM'S HEAD
B ELOW HIPS TO PREVENT ASPIR. IF SYMP SUCH AS LOSS OF GAS REFLEX,
CONVUL/UNCON OCCUR BEFORE EMESIS, GASTRIC LAVAGE (ING 2)

Chemical Properties

HCC:F3
Boiling Pt:B.P. Text:286F,141C
Vapor Pres:10.5
Vapor Density:4
Spec Gravity:1.2
Evaporation Rate & Reference:< 0.1 (BUTYL ACETATE=1)
Solubility in Water:NONE
Appearance and Odor:CLEAR, MILD ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT, SPARKS AND OPEN FLAME.

Disposal

Waste Disposal Methods:INCINERATE IN ACCORDANCE WITH POLLUTION CONTROL
REGULATIONS, OR USE OTHER METHODS FOR DISPOSAL WHICH ARE IN
COMPLIANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.